技術文件
規格
Brand
KeithleyMultimeter Type
Bench
Model Number p
2182A/E
Display Type
Digital
Functions Measured
DC Voltage, Resistance, Temperature
Absolute Maximum Resistance Measurement
1MΩ
Absolute Maximum DC Voltage Measurement
10V dc
Absolute Maximum AC Voltage Measurement
100V ac
Absolute Maximum Temperature Measurement
+1820°C
True RMS
No
Maximum Frequency
400Hz
DC Voltage Measurement Resolution
1µV dc
Weight
5kg
Height
89mm
Minimum Operating Temperature
0°C
Maximum Operating Temperature
+50°C
Dimensions
89 x 213 x 370mm
Best Temperature Measurement Accuracy
±0.2 °C
Best DC Voltage Accuracy
±0.005% + 4 Digits
Width
213mm
Length
370mm
原產地
China
產品詳情
Keithley 2182A Nanovoltmeter
The two-channel 2182A is optimised for making stable, low noise voltage measurements and for characterising low-resistance materials reliably and repeatedly. It provides higher measurement speed and better noise performance than alternative low voltage measurement solutions. The ability to select from a wide range of response times facilitates optimising speed/noise trade-offs. Low noise levels are assured over a wide range of useful response times, typically 15nV p-p noise at 1s response time and 40-50nV p-p noise at 60ms.
Keithley
77,898.20 MOP
77,898.17 MOP Each (不含稅)
1
77,898.20 MOP
77,898.17 MOP Each (不含稅)
暫時無法取得庫存資訊。
1
暫時無法取得庫存資訊。
技術文件
規格
Brand
KeithleyMultimeter Type
Bench
Model Number p
2182A/E
Display Type
Digital
Functions Measured
DC Voltage, Resistance, Temperature
Absolute Maximum Resistance Measurement
1MΩ
Absolute Maximum DC Voltage Measurement
10V dc
Absolute Maximum AC Voltage Measurement
100V ac
Absolute Maximum Temperature Measurement
+1820°C
True RMS
No
Maximum Frequency
400Hz
DC Voltage Measurement Resolution
1µV dc
Weight
5kg
Height
89mm
Minimum Operating Temperature
0°C
Maximum Operating Temperature
+50°C
Dimensions
89 x 213 x 370mm
Best Temperature Measurement Accuracy
±0.2 °C
Best DC Voltage Accuracy
±0.005% + 4 Digits
Width
213mm
Length
370mm
原產地
China
產品詳情
Keithley 2182A Nanovoltmeter
The two-channel 2182A is optimised for making stable, low noise voltage measurements and for characterising low-resistance materials reliably and repeatedly. It provides higher measurement speed and better noise performance than alternative low voltage measurement solutions. The ability to select from a wide range of response times facilitates optimising speed/noise trade-offs. Low noise levels are assured over a wide range of useful response times, typically 15nV p-p noise at 1s response time and 40-50nV p-p noise at 60ms.