Industrial Surge Protector, 120kA, 250 V ac, DIN Rail Mount

RS 庫存號: 502-8687品牌: Phoenix Contact製造商零件號: 2859521
brand-logo

技術文件

規格

Voltage Protection Rating

250V ac

Maximum Surge Current

120kA

Mounting Style

DIN Rail

Impulse Discharge Current

60kA

Length

98.5mm

Width

49.2mm

Depth

70mm

Dimensions

98.5 x 49.2 x 70mm

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

+80°C

Operating Temperature Range

-40 → +80 °C

原產地

Germany

產品詳情

Single & 3-phase Mains FLT & VAL Series

Pluggable modules on a fixed base element, for easy installation and fast replacement.

Standards

IEC 61643, VDE V 0185-3

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

醞釀。 創造。 合作

免費加入

無隱藏費用!

design-spark
design-spark
  • 下載並使用我們的 DesignSpark 軟體進行 PCB 和 3D 機械設計
  • 查看網站內容和論壇
  • 下載超過一百萬種產品的 3D 模型、原理圖和封裝
請點擊這裡了解更多
You may be interested in

P.O.A.

Industrial Surge Protector, 120kA, 250 V ac, DIN Rail Mount

P.O.A.

Industrial Surge Protector, 120kA, 250 V ac, DIN Rail Mount

暫時無法取得庫存資訊。

暫時無法取得庫存資訊。

醞釀。 創造。 合作

免費加入

無隱藏費用!

design-spark
design-spark
  • 下載並使用我們的 DesignSpark 軟體進行 PCB 和 3D 機械設計
  • 查看網站內容和論壇
  • 下載超過一百萬種產品的 3D 模型、原理圖和封裝
請點擊這裡了解更多
You may be interested in

技術文件

規格

Voltage Protection Rating

250V ac

Maximum Surge Current

120kA

Mounting Style

DIN Rail

Impulse Discharge Current

60kA

Length

98.5mm

Width

49.2mm

Depth

70mm

Dimensions

98.5 x 49.2 x 70mm

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

+80°C

Operating Temperature Range

-40 → +80 °C

原產地

Germany

產品詳情

Single & 3-phase Mains FLT & VAL Series

Pluggable modules on a fixed base element, for easy installation and fast replacement.

Standards

IEC 61643, VDE V 0185-3

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.