Atrato Atrato Series Ultrasonic Flow Meter for Liquid, 2 mL/min Min, 500 ml/min Max

RS 庫存號: 136-6374品牌: Atrato製造商零件號: 710-V10-D-RS
brand-logo

技術文件

規格

Brand

Atrato

Media Monitored

Liquid

Device Type

Ultrasonic

Minimum Flow Rate

2 mL/min

Maximum Flow Rate

500 ml/min

Supply Voltage

10 → 24 V dc

Pipe Diameter Range

1/2 in

Connection Type

1/2 BSP Male

Maximum Pressure

10bar

Material

Aluminium

Minimum Media Temperature

-10 °C

Maximum Media Temperature

+110°C

Minimum Operating Temperature

-10 (Enclosed Electronics) °C, -10 (Remote) °C, -10 (Sensor) °C

Maximum Operating Temperature

+110 (Sensor) °C, +60 (Remote) °C, -60 (Enclosed Electronics) °C

Series

Atrato

Current Rating

20 mA

原產地

United Kingdom

產品詳情

Atrato Ultrasonic Flowmeter

The Atrato ultrasonic flowmeter delivers unprecedented performance and accuracy across a broad dynamic range. It has been designed with a clean bore structure that makes it ideal for a range of low flow applications from laminar to turbulent. The Atrato uses patented ’time of flight’ technology that allows it to operate with excellent accuracy and can monitor flow over a range of 200:1. It is easy to connect to a computer by using the USB port to monitor rate and total. It is also possible to modify certain operating parameters like pulse resolution and units.

8,907.80 MOP

8,907.85 MOP Each (不含稅)

Atrato Atrato Series Ultrasonic Flow Meter for Liquid, 2 mL/min Min, 500 ml/min Max

8,907.80 MOP

8,907.85 MOP Each (不含稅)

Atrato Atrato Series Ultrasonic Flow Meter for Liquid, 2 mL/min Min, 500 ml/min Max

暫時無法取得庫存資訊。

暫時無法取得庫存資訊。

技術文件

規格

Brand

Atrato

Media Monitored

Liquid

Device Type

Ultrasonic

Minimum Flow Rate

2 mL/min

Maximum Flow Rate

500 ml/min

Supply Voltage

10 → 24 V dc

Pipe Diameter Range

1/2 in

Connection Type

1/2 BSP Male

Maximum Pressure

10bar

Material

Aluminium

Minimum Media Temperature

-10 °C

Maximum Media Temperature

+110°C

Minimum Operating Temperature

-10 (Enclosed Electronics) °C, -10 (Remote) °C, -10 (Sensor) °C

Maximum Operating Temperature

+110 (Sensor) °C, +60 (Remote) °C, -60 (Enclosed Electronics) °C

Series

Atrato

Current Rating

20 mA

原產地

United Kingdom

產品詳情

Atrato Ultrasonic Flowmeter

The Atrato ultrasonic flowmeter delivers unprecedented performance and accuracy across a broad dynamic range. It has been designed with a clean bore structure that makes it ideal for a range of low flow applications from laminar to turbulent. The Atrato uses patented ’time of flight’ technology that allows it to operate with excellent accuracy and can monitor flow over a range of 200:1. It is easy to connect to a computer by using the USB port to monitor rate and total. It is also possible to modify certain operating parameters like pulse resolution and units.