Pilz 110 V ac Safety Relay - Single Channel With 2 Safety Contacts PNOZ X Range Compatible With Safety Switch/Interlock

RS 庫存號: 324-7252品牌: Pilz製造商零件號: 774053
brand-logo

技術文件

規格

Brand

Pilz

Supply Voltage

110V ac

Number of Channels

1

Safety Contacts

2

Function

Emergency Stop

Reset Method

Automatic, Manual, Monitored

Range

PNOZ X

Safety Category ISO 13849-1

2

Safety Category (ISO 13849-1)

2

PL ISO 13849-1

e

PL (ISO 13849-1)

e

SIL IEC 61508

3

SIL (IEC 61508)

3

Terminal Type

Screw

Series

PNOZ X7

Width

22.5mm

Depth

121mm

Performance Level

e

Length

87mm

產品詳情

PNOZ X7 series by PILZ, Single Channel

The PNOZ X7 range of Safety Relays by PILZ introduces your circuit to a safety related interruption wherein the primary applications are typically in potential hazardous environments where you need that quick power cut off. Particularly useful in automated environments with high foot traffic such as factories, warehouse and the like.

Warning

! This device is not suitable for non-contact barriers as there is no way to initiate a dynamic start and also the unit can be started during the delay-on de-energisation time !

1,576.30 MOP

1,576.25 MOP Each (不含稅)

Pilz 110 V ac Safety Relay - Single Channel With 2 Safety Contacts PNOZ X Range Compatible With Safety Switch/Interlock

1,576.30 MOP

1,576.25 MOP Each (不含稅)

Pilz 110 V ac Safety Relay - Single Channel With 2 Safety Contacts PNOZ X Range Compatible With Safety Switch/Interlock

暫時無法取得庫存資訊。

暫時無法取得庫存資訊。

技術文件

規格

Brand

Pilz

Supply Voltage

110V ac

Number of Channels

1

Safety Contacts

2

Function

Emergency Stop

Reset Method

Automatic, Manual, Monitored

Range

PNOZ X

Safety Category ISO 13849-1

2

Safety Category (ISO 13849-1)

2

PL ISO 13849-1

e

PL (ISO 13849-1)

e

SIL IEC 61508

3

SIL (IEC 61508)

3

Terminal Type

Screw

Series

PNOZ X7

Width

22.5mm

Depth

121mm

Performance Level

e

Length

87mm

產品詳情

PNOZ X7 series by PILZ, Single Channel

The PNOZ X7 range of Safety Relays by PILZ introduces your circuit to a safety related interruption wherein the primary applications are typically in potential hazardous environments where you need that quick power cut off. Particularly useful in automated environments with high foot traffic such as factories, warehouse and the like.

Warning

! This device is not suitable for non-contact barriers as there is no way to initiate a dynamic start and also the unit can be started during the delay-on de-energisation time !