ABB Safety Controller

RS 庫存號: 733-4824品牌: ABB製造商零件號: 2TLA020070R2000 IDFIX-RDistrelec Article No.: 30410110
brand-logo

技術文件

規格

Brand

ABB

Accessory Type

Identifier

For Use With

Pluto Safety Controller

原產地

Estonia

產品詳情

Pluto Safety PLC, Base Unit

Pluto from ABB is an "All-Master" safety PLC concept, which simplifies the design of safety systems and achieves the highest safety category 4 according to EN 954-1. All Pluto's are Master units and can see the other Pluto's inputs, outputs and global memories. This enables the Pluto to evaluate the information from the other Pluto's and then take decisions concerning its own safety devices. The Gateway units are available for several different bus systems, i.e. Profibus, CanOpen, Devicenet and Ethernet. Of Pluto's inputs (the smallest unit has 16 I/O), thus can be configured as either inputs or outputs. In the Pluto family by ABB most modules have dual safety outputs - potential free or PNP types. In a two-wire bus system up to 32 Pluto units can be safely connected and communicate with a superior system via a Gateway or HMI displays. Therefore within a maximum extended system 1472 I/O's can be connected. Also all input components may be connected in series for even more complexity and optimisation.

Approvals

TUV, FS, CSA

164.40 MOP

164.36 MOP Each (不含稅)

ABB Safety Controller

164.40 MOP

164.36 MOP Each (不含稅)

ABB Safety Controller

暫時無法取得庫存資訊。

暫時無法取得庫存資訊。

技術文件

規格

Brand

ABB

Accessory Type

Identifier

For Use With

Pluto Safety Controller

原產地

Estonia

產品詳情

Pluto Safety PLC, Base Unit

Pluto from ABB is an "All-Master" safety PLC concept, which simplifies the design of safety systems and achieves the highest safety category 4 according to EN 954-1. All Pluto's are Master units and can see the other Pluto's inputs, outputs and global memories. This enables the Pluto to evaluate the information from the other Pluto's and then take decisions concerning its own safety devices. The Gateway units are available for several different bus systems, i.e. Profibus, CanOpen, Devicenet and Ethernet. Of Pluto's inputs (the smallest unit has 16 I/O), thus can be configured as either inputs or outputs. In the Pluto family by ABB most modules have dual safety outputs - potential free or PNP types. In a two-wire bus system up to 32 Pluto units can be safely connected and communicate with a superior system via a Gateway or HMI displays. Therefore within a maximum extended system 1472 I/O's can be connected. Also all input components may be connected in series for even more complexity and optimisation.

Approvals

TUV, FS, CSA