Parker PRT series 0.1s to 3s Pneumatic Timer, 8 bar max

RS 庫存號: 410-498品牌: Parker製造商零件號: PRT-E10
brand-logo

技術文件

規格

Brand

Parker

Maximum Time

3s

Minimum Time

0.1s

Maximum Operating Temperature

+60°C

Manufacturer Series

PRT

Minimum Operating Pressure

3bar

Maximum Operating Pressure

8 bar

Minimum Operating Temperature

-15°C

原產地

France

產品詳情

Timer Module

A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.

Logic Systems

Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.

You may be interested in
Parker 0.18s to 1.8s Pneumatic Timer
P.O.A.Each (不含稅)
Parker 0.4s to 3s Pneumatic Timer
P.O.A.Each (不含稅)

1,851.10 MOP

1,851.09 MOP Each (不含稅)

Parker PRT series 0.1s to 3s Pneumatic Timer, 8 bar max

1,851.10 MOP

1,851.09 MOP Each (不含稅)

Parker PRT series 0.1s to 3s Pneumatic Timer, 8 bar max

暫時無法取得庫存資訊。

暫時無法取得庫存資訊。

You may be interested in
Parker 0.18s to 1.8s Pneumatic Timer
P.O.A.Each (不含稅)
Parker 0.4s to 3s Pneumatic Timer
P.O.A.Each (不含稅)

技術文件

規格

Brand

Parker

Maximum Time

3s

Minimum Time

0.1s

Maximum Operating Temperature

+60°C

Manufacturer Series

PRT

Minimum Operating Pressure

3bar

Maximum Operating Pressure

8 bar

Minimum Operating Temperature

-15°C

原產地

France

產品詳情

Timer Module

A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.

Logic Systems

Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.

You may be interested in
Parker 0.18s to 1.8s Pneumatic Timer
P.O.A.Each (不含稅)
Parker 0.4s to 3s Pneumatic Timer
P.O.A.Each (不含稅)