Hazardous Product

Lascar EL-21CFR-1-LCD Temperature Data Logger, USB, 1 Input Channel(s)

RS Stock No.: 111-8088Brand: LascarManufacturers Part No.: EL-21CFR-1-LCD
brand-logo
View all in Data Loggers

Technical Document

Specifications

Brand

Lascar

Number Of Input Channels

1

Model Number

EL-21CFR-1-LCD

Measurement Parameters

Temperature

Sensor Type

Temperature

Interface Type

USB

Data Logger Type

Temperature

Maximum Temperature Measurement

+80 °C

Power Source

Battery

Best Temperature Measurement Accuracy

±0.5°C

IP Rating

IP67

Minimum Operating Temperature

-35°C

Maximum Operating Temperature

+80°C

Display Type

LCD

Battery Life

2 Years

Temperature Measurement Resolution

0.5°C

Includes

1/2 AA battery and wall mount clip

Battery Type

1/2AA

Alarm

Yes

Number Of Readings Per Channel

16382

Country of Origin

China

Product details

Lascar EasyLog 21CFR Compatible Temperature USB Data Logger with LCD Screen

Lascar EL-21CFR-1-LCD is a standalone data logger capable of measuring and storing more than 16 000 temperature readings over a -35 to +80 °C (-31 to +176 °F) range, with a resolution of 0.5 °C (1 °F). Setting up the logger and viewing downloaded data is easy, by plugging the data logger into the USB port of a PC and using EasyLog 21CFR software. Data can then be graphed, printed and exported to other applications for detailed analysis. The encrypted data has full audit tracking to comply with the requirements of 21CFR Part 11. The LCD can show a variety of temperature information. At the touch of a button, the user can cycle between current, maximum and minimum stored values for temperature.

Features and Benefits

-35 to +80 °C (-31 to +176 °F) measurement range
Internal resolution 0.5 °C (1 °F)
Accuracy (overall error) ±1 °C (±2 °F)
Stores more than 16 000 readings
EasyLog 21CFR software available as a free download
Logging rates between 10 seconds and 12 hours
High contrast LCD, with two and a half digit temperature display function
Immediate, delayed and push-to-start logging
User-programmable alarm thresholds
Use as part of a 21CFR Part 11 compliant system
Protected to IP67 when cap fitted
Dimensions 120 x 25 x 22 mm

Areas of Application

Pharmaceutical fridge monitoring
Environmental and weather monitoring
Agricultural and livestock
Food & drink industries
Building & site monitoring
HVAC

Supplied with

Lithium metal battery BAT 3V6 1/2AA, EasyLog 21CFR software (downloadable)

1,053.70 MOP

1,053.69 MOP Each (ex VAT)

Lascar EL-21CFR-1-LCD Temperature Data Logger, USB, 1 Input Channel(s)

Calibration type

1,053.70 MOP

1,053.69 MOP Each (ex VAT)

Lascar EL-21CFR-1-LCD Temperature Data Logger, USB, 1 Input Channel(s)

Stock information temporarily unavailable.

Calibration type

Stock information temporarily unavailable.

Technical Document

Specifications

Brand

Lascar

Number Of Input Channels

1

Model Number

EL-21CFR-1-LCD

Measurement Parameters

Temperature

Sensor Type

Temperature

Interface Type

USB

Data Logger Type

Temperature

Maximum Temperature Measurement

+80 °C

Power Source

Battery

Best Temperature Measurement Accuracy

±0.5°C

IP Rating

IP67

Minimum Operating Temperature

-35°C

Maximum Operating Temperature

+80°C

Display Type

LCD

Battery Life

2 Years

Temperature Measurement Resolution

0.5°C

Includes

1/2 AA battery and wall mount clip

Battery Type

1/2AA

Alarm

Yes

Number Of Readings Per Channel

16382

Country of Origin

China

Product details

Lascar EasyLog 21CFR Compatible Temperature USB Data Logger with LCD Screen

Lascar EL-21CFR-1-LCD is a standalone data logger capable of measuring and storing more than 16 000 temperature readings over a -35 to +80 °C (-31 to +176 °F) range, with a resolution of 0.5 °C (1 °F). Setting up the logger and viewing downloaded data is easy, by plugging the data logger into the USB port of a PC and using EasyLog 21CFR software. Data can then be graphed, printed and exported to other applications for detailed analysis. The encrypted data has full audit tracking to comply with the requirements of 21CFR Part 11. The LCD can show a variety of temperature information. At the touch of a button, the user can cycle between current, maximum and minimum stored values for temperature.

Features and Benefits

-35 to +80 °C (-31 to +176 °F) measurement range
Internal resolution 0.5 °C (1 °F)
Accuracy (overall error) ±1 °C (±2 °F)
Stores more than 16 000 readings
EasyLog 21CFR software available as a free download
Logging rates between 10 seconds and 12 hours
High contrast LCD, with two and a half digit temperature display function
Immediate, delayed and push-to-start logging
User-programmable alarm thresholds
Use as part of a 21CFR Part 11 compliant system
Protected to IP67 when cap fitted
Dimensions 120 x 25 x 22 mm

Areas of Application

Pharmaceutical fridge monitoring
Environmental and weather monitoring
Agricultural and livestock
Food & drink industries
Building & site monitoring
HVAC

Supplied with

Lithium metal battery BAT 3V6 1/2AA, EasyLog 21CFR software (downloadable)