Technical Document
Specifications
Brand
RecomProduct Type
Switching Regulator
Output Current
500mA
Mount Type
Through Hole
Power
7.5W
Efficiency
91%
Ripple and Noise
20mV Pk-Pk
Minimum Operating Temperature
-40°C
Maximum Operating Temperature
85°C
Series
R-78HB
Package Type
SIP
Line Regulation
±1 %
Depth
17.5mm
Length
11.5mm
Weight
4g
Standards/Approvals
REACH
Maximum Input Voltage
72V dc
MTBF
7395000h
Load Regulation
±0.6 %
Minimum Input Voltage
20V
Country of Origin
Taiwan, Province Of China
Product details
R78HBxx-0.5 Series
Non-isolated
Medical safety approval EN-60601-1-2
High efficiency switching regulator, up to 96%
No need for heatsinks
Very wide input voltage range, up to 72V
Low ripple and noise
Thermal shutdown and continuous short circuit protection
Pin compatible with LM78xx Linears
Industry standard SIP-3 package
Standards
EN-55022, EN-55024, EN-60601-1-2, EN-60950-1
Stock information temporarily unavailable.
128.70 MOP
128.71 MOP Each (ex VAT)
Standard
1
128.70 MOP
128.71 MOP Each (ex VAT)
Stock information temporarily unavailable.
Standard
1
| quantity | Unit price |
|---|---|
| 1 - 10 | 128.71 MOP |
| 11 - 20 | 125.51 MOP |
| 21+ | 123.45 MOP |
Technical Document
Specifications
Brand
RecomProduct Type
Switching Regulator
Output Current
500mA
Mount Type
Through Hole
Power
7.5W
Efficiency
91%
Ripple and Noise
20mV Pk-Pk
Minimum Operating Temperature
-40°C
Maximum Operating Temperature
85°C
Series
R-78HB
Package Type
SIP
Line Regulation
±1 %
Depth
17.5mm
Length
11.5mm
Weight
4g
Standards/Approvals
REACH
Maximum Input Voltage
72V dc
MTBF
7395000h
Load Regulation
±0.6 %
Minimum Input Voltage
20V
Country of Origin
Taiwan, Province Of China
Product details
R78HBxx-0.5 Series
Non-isolated
Medical safety approval EN-60601-1-2
High efficiency switching regulator, up to 96%
No need for heatsinks
Very wide input voltage range, up to 72V
Low ripple and noise
Thermal shutdown and continuous short circuit protection
Pin compatible with LM78xx Linears
Industry standard SIP-3 package
Standards
EN-55022, EN-55024, EN-60601-1-2, EN-60950-1