Brand
HartingProduct Type
Hinged Frame
Accessory Type
Hinged Frame
Size
6B
Cable Entry Angle
Top
Series
Han-Modular
For Use With
Han Modular 2 Module A-B
Material
Stainless Steel
Standards/Approvals
No
Minimum Wire Size mm²
1mm²
Maximum Wire Size mm²
10mm²
原產地
Germany
產品詳情
This hinged frame provides a robust mounting solution for two-module Han Modular A-B insert assemblies, designed for industrial connector environments where top-cable entry is required. It is intended for use within control panels and equipment racks to allow hinged access to connected modules, with construction suited to harsh operational conditions and frequent mating cycles.
Power conductors may be up to 10mm² while signal conductors accept 0.5–2.5mm²
ferrules are recommended and mandatory for 10mm² when using the specific ferrule crimping tool.
Use a slotted 0.6 x 3.5mm or PH2 screwdriver, with PE screw tightening torques of 0.8 Nm for M3 and 1.2 Nm for M4.
It is specified to operate continuously between −40°C and +125°C, suitable for elevated thermal demands.
The frame conforms to relevant IEC connector standards and holds approvals including UL/CSA and DNV GL for applicable installations.
DNV GL
UL 1977 ECBT2.E235076
暫時無法取得庫存資訊。
219.20 MOP
219.19 MOP Each (不含稅)
1
219.20 MOP
219.19 MOP Each (不含稅)
暫時無法取得庫存資訊。
1
| 數量 | 單價 |
|---|---|
| 1 - 24 | 219.19 MOP |
| 25 - 49 | 213.11 MOP |
| 50+ | 204.35 MOP |
技術文件
規格
Brand
HartingProduct Type
Hinged Frame
Accessory Type
Hinged Frame
Size
6B
Cable Entry Angle
Top
Series
Han-Modular
For Use With
Han Modular 2 Module A-B
Material
Stainless Steel
Standards/Approvals
No
Minimum Wire Size mm²
1mm²
Maximum Wire Size mm²
10mm²
原產地
Germany
產品詳情
This hinged frame provides a robust mounting solution for two-module Han Modular A-B insert assemblies, designed for industrial connector environments where top-cable entry is required. It is intended for use within control panels and equipment racks to allow hinged access to connected modules, with construction suited to harsh operational conditions and frequent mating cycles.
Power conductors may be up to 10mm² while signal conductors accept 0.5–2.5mm²
ferrules are recommended and mandatory for 10mm² when using the specific ferrule crimping tool.
Use a slotted 0.6 x 3.5mm or PH2 screwdriver, with PE screw tightening torques of 0.8 Nm for M3 and 1.2 Nm for M4.
It is specified to operate continuously between −40°C and +125°C, suitable for elevated thermal demands.
The frame conforms to relevant IEC connector standards and holds approvals including UL/CSA and DNV GL for applicable installations.
DNV GL
UL 1977 ECBT2.E235076